Exit demo 5V0-22.23 VMware vSAN Specialist v2 PDF format · free preview

VMware 5V0-22.23 - Questions & Answers

Free preview · every answer includes a full explanation

Product page: https://prepkeys.com/5v0-2223.html

Question 1
Multiple choice

An administrator wants to assign a storage policy to a workload on a two-node vSAN OSA cluster consisting of three disk groups each with nested fault domains. The virtual machine must be protected against a disk or disk group failure.

Which two storage policies meet these requirements? (Choose two.)

A.

RAID-5/FTT 2

B.

RAID-1/FTT 3

C.

RAID-6/FTT 2

D.

RAID-5/FTT 1

E.

RAID-1/FTT 1

Question 2
Single choice

A vSAN administrator has a vSAN cluster that is using vSphere Lifecycle Manager (vLCM) to manage hypervisor, server drivers, and firmware. All hosts in the cluster are compliant according to the vLCM image.

A 10GB NIC on the servers is experiencing issues, and the vSAN administrator determines a new network driver will resolve the problem. Unfortunately, the required NIC driver is a newer version compared to the driver provided by the most recent Vendor Add-on.

Which action should the vSAN administrator take to ensure the latest network driver is installed on the NIC before remediation?

A.

Make sure the vLCM image is configured to use the most recent version of the Vendor Add-on

B.

Add an individual component to the vLCM image that has the updated NIC driver

C.

Remove theVendor Add-on from the vLCM image, and then manually install the network driver on the servers

D.

Modify the vLCM image to omit the NIC Driver, and then manually update the servers with the required
NIC driver

Question 3
Single choice

A vSAN administrator has a cluster configured with a Storage Pool that was moved to a new physical DC.

Upon checking on the vSAN cluster health status, one of the ESXi hosts has two storage devices in a degraded state and must be replaced.

What must the vSAN administrator do to restore the health of the vSAN cluster with minimum risk?

A.

Remove the host from ySAN configuration, replace the faulty disks, re-create the storage pool

B.

Remove the entire storage pool, install the new devices, re-create the storage pool

C.

Remove the host from the cluster, replace the faulty disks, re-add the host to the cluster

D.

Remove the devices from the storage pool, replace the storage devices, claim the new devices in vSAN

Question 4
Single choice

A six-node vSAN ESA cluster contains multiple virtual machines, and a vSAN storage policy with the rule
"Failures to tolerate" set to "1 failure - RAID-5 (Erasure Coding)" is assigned. A vSAN administrator has changed the rule in the assigned policy to "2 failures - RAID-6 (Erasure Coding)".

What is the result of this change?

A.

No changes occur until the policy is reapplied.

B.

The changes are queued for 60 minutes.

C.

The policy change is rejected immediately.

D.

The updated policy is serially applied to the virtual machines.

Question 5
Single choice

A host in a vSAN stretched cluster goes offline during an unplanned event.

Which action will be triggered from AQC on the vSAN cluster?

A.

AQC will trigger a vMotion of VMs that went offline.

B.

AQC will restart the VMs that went offline.

C.

AQC will recalculate the quorum on an object.

D.

AQC will create a vSAN alarm.

Question 6
Single choice

What is the minimum required number of hosts to provide data redundancy for a vSAN stretched cluster using dual-site mirroring and local protection with 1 failure - RAID-1 (Mirroring)?

A.

3 hosts

B.

3 hosts

C.

4 hosts

D.

6 hosts

Question 7
Single choice

A vSAN administrator was presented with 30 additional vSAN ReadyNodes to add to an existing vSAN cluster. There is only one administrator to complete this task.

What is the fastest approach?

A.

Run vim-cmd to capture, and apply the configuration from an existing host

B.

Launch Quickstart to Add Hosts to a vSAN Cluster

C.

Clone the ESXi boot partition to all new hosts, since the hardware is identical

D.

Use a Host Profile that was extracted from an existing host

Question 8
Multiple choice

What are two prerequisites for using the TRIM and UNMAP capability of vSAN? (Choose two.)

A.

Deduplication and compression are enabled.

B.

The vSAN cluster is an all-flash architecture.

C.

The VM quest operating system supports ATA TRIM or SCSI UNMAP capability

D.

TRIM and UNMAP is enabled.

E.

Change the Object Space Reservation to 100.

Question 9
Single choice

An administrator has deployed a new vSAN OSA cluster that contains eight hosts and needs to configure a storage policy for the currently deployed database virtual machines. The requirements state that if two hosts in the vSAN OSA cluster fail, all virtual machines are unaffected.

Which RAID configuration must the administrator use in this storage policy to achieve the best performance for the database virtual machines?

A.

RA1D-1

B.

RAID-5

C.

RAID-6

D.

RAID-0

Question 10
Single choice

A customer has deployed a new vSAN cluster with the following configuration:

5 x vSAN ReadyNodes

All Flash

12 TB Raw Storage

vSAN 8 is deployed with ESA.

New VMs are configured with a RAID-5 VM policy.

Which statement is accurate?

A.

vSAN will use a 2+1 RAID-5 data placement scheme with parity will be used

B.

RAID 5 will provide an FTT=2 level of protection in this case

C.

vSAN will use a 4+1 RAID-5 data placement scheme with parity will be used

D.

vSAN will spread the components across all of the disk groups

Showing 10 of 75 questions · Unlock the full set